AUBURN HILLS, Mich., March 31, 2015 /PRNewswire-USNewswire/ -- The efficacy of continuous UV-C disinfection robots versus pulsed xenon (PU-UX) was highlighted in a recently published study1 of ultraviolet (UV) light disinfection systems by an influential infection prevention research team, including Curtis Donskey, M.D.  The study tested a continuous UV-C robot which was run for the same length of time from the same point in the room as a pulsed xenon (PU-UV) unit.  The results showed surprisingly low pathogen kill rates for the pulsed xenon device, about .5 log for both C.diff and VRE, even as close as 4 feet1 (see photo).  The continuous UV-C robot clearly demonstrated a much higher CFU reduction for the pathogens C.difficile, MRSA and VRE.  The study states, "PX-UV was less effective than continuous UV-C in reducing pathogen recovery on glass slides with a 10-minute exposure time in similar hospital rooms"1 and "the UV-C device achieved significantly greater log10CFU reductions than the PX-UV device" 1 (emphasis added).  It's important to note that not only did the continuous UV-C robot in the study show much stronger disinfectant results, but that it was not run for its entire cycle time. 

Graph 1 - Chart from VA Donskey study: Study results showing log reductions achieved by a UV-C and pulsed xenon devices when run for the same time (10 min.) at the same distance from glass microscope slides (4 ft).

The study calls attention to the dangers of trying to complete a disinfectant procedure too quickly and under-dosing as a result.  The study states, "Although the PX-UV device reduced contamination on surfaces, residual contamination was not uncommon"1  and "the log reduction achieved by PX-UV on carriers at 10 minutes were relatively modest." 1 "In an effort to speed up the cleaning process, EVS and IP taffs may be misleading themselves about how well the pulsed xenon treated rooms are really disinfected," says Kenny.  "Hospitals must be wary of bold claims of speed and efficacy made by manufacturers of pulsed xenon units that simply don't stand up to scrutiny as clearly shown in the Donskey study.  We're pleased with the results of the study as it unambiguously exposes the inherent weakness of the pulsed xenon units," he stated.  Kenny added, "IPT's IRiS 3200m is over twice as powerful as the continuous UV-C device in the study and 25 times more powerful than the xenon pulse unit.  Given that the pulsed xenon unit has to be moved around several times just to treat a single room, it really debunks the myth that pulsed xenon units are faster than continuous UV-C robots."  



Effective dosage of the treatment area is a critically important factor when choosing a UV-C disinfectant system.  Infection Prevention Technologies (IPT) IRiS™ robots employ real-time  "Smart-Dose UV-C" technology to determine how long to treat a room taking the guess work away from the hospital staff.  "Guessing how long to run your UV-C system is not good science.   Unless you are measuring the UV-C dosage in real-time with UV sensors you may be under-dosing the room," stated Tom Kenny, CEO of Infection Prevention Technologies.

The study also points out that "the efficacy of PX-UV was dramatically reduced as the distance from the device was increased."1  The net effect is that pulsed xenon devices (PX-UV) require multiple treatments in a single room.  The IRiS™ family of intelligent robots use patented "Power-Boost" and "Field Balancing™" technologies resulting in whole-room treatments and faster treatment times.  These UV power enhancement technologies are designed to enable the IRiS UV-C robots to disinfect even shadow areas in a single treatment without moving the robot around. 


Industry leading UV-C power from the IRiS™ family of intelligent disinfectant robots results in faster room treatments, whole room treatments, and more effective treatments.

1 -  Michelle M. Nerandzic, Priyaleela Thota, Thriveen Sankar C., Annette Jencson, Jennifer L. Cadnum, Amy J. Ray, Robert A. Salata, Richard R. Watkins and Curtis J. Donskey (2015). Evaluation of a Pulsed Xenon Ultraviolet Disinfection System for Reduction of Healthcare-Associated Pathogens in Hospital Rooms. Infection Control & Hospital Epidemiology, 36, pp 192-197. doi:10.1017/ice.2014.36. http://journals.cambridge.org/action/displayFulltext?type=6&fid=9491737&jid=ICE&volumeId=-1&issueId=-1&aid=9491736&bodyId=&membershipNumber=&societyETOCSession=&fulltextType=RA&fileId=S0899823X14000361

About Infection Prevention Technologies, LLC
Infection Prevention Technologies provides the most powerful, automated UV-C infection prevention robot systems in the world.  IPT's IRiS™ product family offers patented "Field-Balancing™" and "Power-Boost" technologies allowing for single in-room placement and treatment, resulting in fast and effective whole room treatment including indirect or shadowed surfaces.  IPT's Steri-Trak™ software offers secure, real-time web based data for job scheduling, tracking and management. For more information, visit www.infectionpreventiontechnologies.com

Editor's Note:  Contact Chris Batts ([email protected]) for additional product information and images.

CONTACT: Chris Batts, 248.481.9899

Photo - http://photos.prnewswire.com/prnh/20150330/195233

 

To view the original version on PR Newswire, visit:http://www.prnewswire.com/news-releases/va-funded-study-validates-continuous-uv-c-technology-for-pathogen-reduction-300057832.html

SOURCE Infection Prevention Tecnologies, LLC


[ Back To TMCnet.com's Homepage ]